SEMI HERMETIC COMPRESSOR :
Sucks from the vaporizer/evaporator gaseous refrigerant, which is found under
the low pressure, and after pressing it forces under the high pressure, in the
form of hot gas into the capacitor/condenser.Air pumps for the cooling
installations are produced in three forms:airtight, polugermetichnye and
stuffing box (opened).In the compressors of small power is used the lubrication
system by a sputtering, in the compressors of large power- circulating under the
pressure.In addition to this, after specific cold output in the large
compressors are established/installed the systems of unloading start and control
of power.Cooling cylinder heads usually air, in certain cases large compressors
have water cooling system.On the jacket/housing of the compressor of IMET (
Institute of Metallurgy im. A. A. Baykov) the index of the oil level in the
crankcase, is also possible the installation of crankcase podogrevatedya.
To
Top
HERMETIC COMPRESSOR :
Sucks from the vaporizer/evaporator gaseous refrigerant, which is found under
the low pressure, and after pressing it forces under the high pressure, in the
form of hot gas into the capacitor/condenser.Air pumps for the cooling
installations are airtight
To Top
EVAPORATOR (CHILLER TYPE) :
Evaporates under the low by pressure and the temperature the refrigerant,
introduced by the heat-control valve/gate, in this case the water, which is
located in the jacket/housing, is cooled.The shell-and-tube heat exchanger is
airtight balon with a number of copper pipes over which it flows/occurs gaseous
refrigerant.Cooling water occurs in the medium of that being located between the
copper tubes and the jacket/housing.External the side of jacket/housing is
insulated by the heat insulator of necessary they are made look fatter.
To Top
EVAPORATOR (DIPPING BATARY TYPE) :
Evaporates under the low by pressure and the temperature the refrigerant,
introduced by the heat-control valve/gate, in this case the water, which is
located in the tank, is cooled.Immersion heat exchanger is placed into the open
tank.It is copper coil with the alyumin'evym ribbing.Cooling also occurs during
the flow of gaseous refrigerant on the copper tubes.Water is cooled, penetrating
the tank with the contact with the heat exchanger.The outer side of tank is
insulated by the heat insulator of that being suitable/approaching they are made
look fatter.
To Top
LOW HIGH
PRESSURE PROCESSOR :
Prevents/warns reduction or increase in the pressure beyond the lower and
upper limits on the lines of suction and forcing.With the normal operation the
contacts of regulator are locked.On leaving of pressure beyond the limits
established/installed by firm by producer the regulator disconnects the
electrical motor of the compressor.
To Top
HIGH
PRESSURE PROCESSOR (FAN AUTOMATIC) :
For the creation by the fans of air circulation, which cools
capacitor/condenser, it includes or turns off/disconnects their vzavisimosti
flow from the pressure of the refrigerant.
To Top
SIGHTGLASS :
It is found on the line of the liquid coolant and gives the possibility of
visual observation of it.
To Top
THERMOSTATIC EXPANSION VALF :
The heat-control valve/gate, which is found on the line of liquid circuit, by
means of the sensor, bulb on the line of the suction of cooler, monitors a
quantity of refrigerant, introduced into the vaporizer/evaporator, i.e.,
directly regulates cold output.In the installations of small power primnyayutsya
the valves/gates with the internal pressure equalization.Usually on the housing
they have a regulator of the introduction/input of the refrigerant.
To
Top
FLOW-SWITCH :
It is mounted in the line of the heat exchanger of the cooler of water (it is
used only in the aggregates/units with the shell-and-tube heat exchangers)
during lowering in the level or curtailment of the flow water-cooled it stops
the work of the aggregate/unit
To
Top
DIGITAL MANAGEMENT THERMOSTAT:
It adjusts the required cold output of installation, by supplying
electrical signals, to solenoid valve monitors the power of cooler. The
temperature sensor of instrument is placed in the balloon or the tank where it
easily it comes into contact with water-cooled. The desired temperature of the
cold water is established/installed on the panel
To Top
DRYER :
It prevents the blockage/soiling system by ice, which is formed at low
temperatures because of the moisture, which remained in the system during its
installation.It is mounted on the line of the liquid coolant.Also filters
postoroniye of admixture/impurity in the refrigerant.
To Top
MANOMETERS :
High-pressure gage;precise pressure on the delivery line and
temperature of condensation in the capacitor/condenser are determined.
Low-pressure manometer;precise pressure on the lines of suction and
temperature of evaporation in the vaporizer/evaporator are determined
To
Top
ELECTRICITY CONTROL PANEL AND TABLE :
It automatically governs/controls the work of installation.It is mounted on
the front of the jacket/housing.On the panel:safety devices/fuses, relay,
contactors, terminal, the group of signal and measuring meters.Panel shows
working order and malfunctions.
To
Top
WATER PUMP :
It is established/installed for creating the circulation water-cooled between
the cooler and the cooled body.
To Top
SELENOID VALF :
Valve/gate for discovery/opening or overlapping the supply of liquid or
vaporous circuit, controlled by electric current.Depending on functions or
destinations of aggregate/unit it is mounted on the line of liquid or gaseous
circuit.In obtaining of signal from processor or thermoregulator it
opens/discloses or overlaps the circuit.Usually valve/gate is closed with the
cut of electric current.
To Top
CONDENSER FAN :
Is created air flow of that cooling the capacitors/condensers.